Gujarat Heavy Chemicals Ltd (India)

From Efficiency Finder
Jump to navigationJump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Back to EFFICIENCY FINDER FOR CHEMICAL INDUSTRY

Back to Information about organic pigments and dyes


Visit Report to M/s.Gujarat Heavy Chemicals Ltd.

Nemeli Road, Tiruporur, Kanchipuram Dist. 603 110. Tamilnadu, India

Date : 19/06/2003.
Product used for drying = Salt
Source used for drying = Thermic Fluid
Name of the fuel used = Furnace oil
Fuel used per hour = 100 litres ( as per report)
Fuel used per hour = 135 - 150 litres (as per personal enquiry)
Fuel used per day = 2400 litres
Fuel used per year = 640 kilo litres
Approximate cost of Fuel = Rs.13.25/litres
Method of drying = FBD (Fluidised Bed Drying)
Capacity of drier = 15 tonnes
Initial moisture of the product = 4.5%
Final moisture of the product = 0.13%
Annual production = around 75,000 mt
Capacity of heating system = 15 lakh Kcals/hr.
Total shifts = 3 shifts (24 hr.)
Tilting angle of factory = 11o SE (south towards east)


Total blowers used for drying = 2 Nos.
Main Heating Blower = 1 no Exhaust Blower = 1 no


Main Heating Blower specification
Blower power = 75 HP
Measured Current & Voltage = 72.5A, 420V


Volume flow of the main blower (measured at blower suction side)
Circumference of the pipe = 1.63m (diameter of the pipe = 0.52m)
Cross sectional area of the pipe = 0.212m2
Average velocity of the air = 22.85 m/s
Volume flow of the air = 17,500 CMH
Blower suction pressure = 57 mm of H2O


Volume flow measured at blower delivery side
Cold air delivery for cooling chamber
Delivery pressure at cold air passage = 635 mm of H2O
Circumference of the pipe = 1.63m (diameter of the pipe = 0.52m)
Cross sectional area of the pipe = 0.212m2
Average velocity of the air = 5.1 m/s
Volume flow of the air = 4,000 CMH


Net volume flow of the air used for drying = [17,500 - 4,000 CMH] = 13,500 CMH
Drier inlet temperature = 2100C
Delivery pressure near thermic fluid = 596 mm of H2O heat exchanger side


Exhaust Blower Specification
Blower Power = 75 HP
Measured Current & Voltage = 57A, 420V


Thermax boiler Specification
Blower Power = 15 HP
Measured Current & Voltage = 8.7A, 420V
Thermic fluid inlet temperature = 2200C Thermic fluid outlet temperature = 270oC
Volume flow of the Exhaust blower (measured at blower suction side)
Circumference of the pipe = 1m (diameter of the pipe = 0.32m)
Cross sectional area of the pipe = 0.08m2
Average velocity of the air = 7.7 m/s
Volume flow of the air = 2,250 CMH
Blower suction pressure = 12 mm of H2O


Energy Balance for Hot Air Generation
Net volume flow of air heated from 35oC - 2100C = 13,500 CMH
Total energy required / hour
= (13,500 x 0.898*)kg. x 1 kJ x (210 – 35)
= 21,21,525 kJ
= 5,07,542 kilo cal.
Density of air at a temperature 1250C - average of 350C & 2100C


Solar Energy Contribution to heat the air from 350C - 1050C
Energy delivery = (13,500 x 0.999*)kg. x 1 kJ x (105 – 35) = 9,44,055 kJ = 2,25,850 kilo cal.
Density of air at a temperature 700C - average of 350C & 1050C


The percentage of energy savings through solar heating = 44.4%


Fuel Savings (assuming 100 litres/hr)
The average fuel savings per day = 100 litres x 0.444 x 7 hr. = 311 litres
The average fuel savings per year = 311 litres x 300 days = 93,300 litres
Fuel savings cost per year = Rs12,12,900/-


Assuming 135 litres/hr The average fuel savings per day = 135 litres x 0.444 x 7 hr. = 420 litres
The average fuel savings per year = 420 litres x 300 days = 1,26,000 litres
Fuel savings cost per year = Rs16,38,000/-